D1000 Gen2 – Battery Junction Unit (BJU)

Overview

The D1000 Gen2 Battery Junction Unit (BJU) serves as the precision monitoring component for current and high-voltage measurements within Prohelion’s distributed battery management architecture. The D1000 Gen2 BMU is designed to be compatible with commercially available high-precision current measurement systems, with primary support for the Isabellenhuette IVT-S. This approach leverages proven, industry-standard technology while providing the specialized integration and configuration needed for seamless operation within the D1000 Gen2 ecosystem. The BJU provides critical pack-level monitoring including battery current, battery voltage, charger voltage, and load voltage measurements, enabling comprehensive system state estimation and safety monitoring.

Commercial Integration: The D1000 Gen2 system utilizes commercially available current measurement technology, specifically the Isabellenhuette IVT-S, ensuring proven reliability while providing optimized integration with Prohelion’s distributed BMS architecture.

Key Features

  • High-Precision Current Measurement: Commercially proven current sensing technology for accurate pack monitoring
  • Multi-Voltage Monitoring: Simultaneous monitoring of battery, charger, and load voltages
  • Seamless BMU Integration: Optimized configuration for D1000 Gen2 BMU compatibility
  • Industrial Reliability: Leverages established commercial technology with proven track record
  • CAN Communication: Integrated communication protocol for real-time data transmission
  • System State Estimation: Enables accurate SOC, SOH, and SOP calculations
  • Safety Monitoring: Critical current and voltage monitoring for system protection
  • Flexible Integration: Compatible with various system configurations and installations

Supported Device: Isabellenhuette IVT-S

The primary supported device for the D1000 Gen2 BJU implementation is the Isabellenhuette IVT-S High Precision Current Measurement System:

  • Proven Technology: Industry-standard current measurement system with established reliability
  • High Precision: Accurate current and voltage measurements for critical battery applications
  • Multi-Channel Monitoring: Supports current measurement and multiple voltage inputs
  • CAN Integration: Built-in CAN communication for seamless system integration
  • Automotive Grade: Designed for demanding automotive and industrial environments
  • Comprehensive Documentation: Full technical documentation and support available

System Configuration

The D1000 Gen2 BMU firmware is configured to work with the IVT-S using the following measurement channel arrangement:

  • Current Channel: Battery pack current measurement for charge/discharge monitoring
  • Voltage 1 (U1): Battery voltage monitoring for pack state assessment
  • Voltage 2 (U2): Charger voltage monitoring for charging system integration
  • Voltage 3 (U3): Load voltage monitoring for system output assessment

Applications

The D1000 Gen2 BJU is essential for comprehensive battery system monitoring:

  • High-voltage electric vehicle battery pack current monitoring
  • Large-scale energy storage system power flow monitoring
  • Industrial battery current and voltage measurement
  • Grid-scale energy storage current measurement
  • Automotive battery management systems requiring precision monitoring
  • Research and development applications requiring accurate pack measurements
  • Critical applications requiring high-precision current sensing
  • Multi-chemistry battery systems with complex charging profiles

System Integration

The BJU integrates as a critical component within the D1000 Gen2 distributed architecture:

  • D1000 Gen2 BMU: Direct communication with the master D1000 Gen2 BMU for centralized monitoring
  • CAN Communication: Real-time data transmission of current and voltage measurements
  • State Estimation: Provides critical data for SOC, SOH, and SOP calculations
  • Safety Integration: Current monitoring for overcurrent protection and system safety
  • Charging Integration: Charger voltage monitoring for charging system coordination
  • Load Monitoring: Load voltage measurement for system output management

Technical Specifications (IVT-S)

  • Measurement Type: High-precision current and voltage measurement
  • Current Measurement: High-accuracy current sensing with wide dynamic range
  • Voltage Channels: 3 independent voltage measurement channels
  • Communication: CAN bus interface for real-time data transmission
  • Environmental Rating: Automotive-grade environmental specifications
  • Power Supply: 12V/24V supply voltage options
  • Mounting: Industrial mounting options for various installations

Benefits of Commercial Integration

  • Proven Reliability: Leverages established commercial technology with proven track record
  • Cost Efficiency: Utilizes volume-produced components for cost-effective solutions
  • Industry Support: Access to comprehensive technical support and documentation
  • Continuous Improvement: Benefits from ongoing commercial product development
  • Global Availability: Worldwide availability through established distribution channels
  • Quality Assurance: Commercial manufacturing quality control and testing

Installation & Configuration

  • BMU Configuration: Pre-configured firmware settings for seamless IVT-S integration
  • CAN Setup: Optimized CAN communication parameters for reliable data transmission
  • Channel Mapping: Standardized channel configuration for consistent system behavior
  • Calibration: Factory calibration for accurate measurements across operating range
  • Integration Testing: Comprehensive testing procedures for system validation
  • Documentation: Complete integration guides and technical specifications

Future Compatibility

The D1000 Gen2 BMU architecture is designed for flexibility and future expansion:

  • Additional Devices: Framework for integrating additional current measurement systems
  • Firmware Updates: Capability to add support for new devices through firmware updates
  • Scalable Architecture: Designed to accommodate various current measurement technologies
  • Industry Evolution: Ready to adopt new current measurement innovations as they become available

Documentation

Comprehensive technical documentation and integration guides are available through:

Support

For technical support, integration assistance, or product inquiries, please visit our support portal where you can find comprehensive resources, submit support tickets, and access our knowledge base for D1000 Gen2 system integration and BJU configuration.

This product is currently out of stock and unavailable.